* [Patch V2] BaseTools: Fix a bug that HII type pcd value display extra 0x00
@ 2018-03-05 6:56 Yonghong Zhu
2018-03-05 7:06 ` Feng, Bob C
0 siblings, 1 reply; 2+ messages in thread
From: Yonghong Zhu @ 2018-03-05 6:56 UTC (permalink / raw)
To: edk2-devel
V2: Add Pcd.DatumType check.
Fix a bug that HII type Pcd value display in the report will have an
extra 0x00, because original code use StringToArray function and it will
judge whether the value length is a multiplier of 2, if not, it will
change the value in Pcd Object and add an extra 0x00.
Cc: Bob Feng <bob.c.feng@intel.com>
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Yonghong Zhu <yonghong.zhu@intel.com>
---
BaseTools/Source/Python/AutoGen/AutoGen.py | 7 ++++++-
BaseTools/Source/Python/Workspace/DscBuildData.py | 6 +-----
2 files changed, 7 insertions(+), 6 deletions(-)
diff --git a/BaseTools/Source/Python/AutoGen/AutoGen.py b/BaseTools/Source/Python/AutoGen/AutoGen.py
index 439e360..c8c042b 100644
--- a/BaseTools/Source/Python/AutoGen/AutoGen.py
+++ b/BaseTools/Source/Python/AutoGen/AutoGen.py
@@ -1329,11 +1329,16 @@ class PlatformAutoGen(AutoGen):
continue
if len(Sku.VariableName) > 0:
VariableGuidStructure = Sku.VariableGuidValue
VariableGuid = GuidStructureStringToGuidString(VariableGuidStructure)
for StorageName in Sku.DefaultStoreDict:
- VariableInfo.append_variable(var_info(Index,pcdname,StorageName,SkuName, StringToArray(Sku.VariableName),VariableGuid, Sku.VariableOffset, Sku.VariableAttribute , Sku.HiiDefaultValue,Sku.DefaultStoreDict[StorageName],Pcd.DatumType))
+ HiiValue = Sku.HiiDefaultValue
+ DefaultStoreVal= Sku.DefaultStoreDict[StorageName]
+ if Pcd.DatumType not in [TAB_UINT8, TAB_UINT16, TAB_UINT32, TAB_UINT64, "BOOLEAN"]:
+ HiiValue = StringToArray(Sku.HiiDefaultValue)
+ DefaultStoreVal = StringToArray(Sku.DefaultStoreDict[StorageName])
+ VariableInfo.append_variable(var_info(Index,pcdname,StorageName,SkuName, StringToArray(Sku.VariableName),VariableGuid, Sku.VariableOffset, Sku.VariableAttribute , HiiValue, DefaultStoreVal,Pcd.DatumType))
Index += 1
return VariableInfo
def UpdateNVStoreMaxSize(self,OrgVpdFile):
if self.VariableInfo:
diff --git a/BaseTools/Source/Python/Workspace/DscBuildData.py b/BaseTools/Source/Python/Workspace/DscBuildData.py
index 9d78770..fc7a307 100644
--- a/BaseTools/Source/Python/Workspace/DscBuildData.py
+++ b/BaseTools/Source/Python/Workspace/DscBuildData.py
@@ -2513,17 +2513,13 @@ class DscBuildData(PlatformBuildClassObject):
else:
MaxSize = 0
if pcd.DatumType not in ['BOOLEAN','UINT8','UINT16','UINT32','UINT64']:
for (_, skuobj) in pcd.SkuInfoList.items():
datalen = 0
- skuobj.HiiDefaultValue = StringToArray(skuobj.HiiDefaultValue)
- datalen = len(skuobj.HiiDefaultValue.split(","))
+ datalen = len((StringToArray(skuobj.HiiDefaultValue)).split(","))
if datalen > MaxSize:
MaxSize = datalen
- for defaultst in skuobj.DefaultStoreDict:
- skuobj.DefaultStoreDict[defaultst] = StringToArray(skuobj.DefaultStoreDict[defaultst])
- pcd.DefaultValue = StringToArray(pcd.DefaultValue)
pcd.MaxDatumSize = str(MaxSize)
rt, invalidhii = self.CheckVariableNameAssignment(Pcds)
if not rt:
invalidpcd = ",".join(invalidhii)
EdkLogger.error('build', PCD_VARIABLE_INFO_ERROR, Message='The same HII PCD must map to the same EFI variable for all SKUs', File=self.MetaFile, ExtraData=invalidpcd)
--
2.6.1.windows.1
^ permalink raw reply related [flat|nested] 2+ messages in thread
* Re: [Patch V2] BaseTools: Fix a bug that HII type pcd value display extra 0x00
2018-03-05 6:56 [Patch V2] BaseTools: Fix a bug that HII type pcd value display extra 0x00 Yonghong Zhu
@ 2018-03-05 7:06 ` Feng, Bob C
0 siblings, 0 replies; 2+ messages in thread
From: Feng, Bob C @ 2018-03-05 7:06 UTC (permalink / raw)
To: Zhu, Yonghong, edk2-devel@lists.01.org
Reviewed-by: Feng, Bob C <bob.c.feng@intel.com>
-----Original Message-----
From: Zhu, Yonghong
Sent: Monday, March 05, 2018 2:56 PM
To: edk2-devel@lists.01.org
Cc: Feng, Bob C <bob.c.feng@intel.com>
Subject: [Patch V2] BaseTools: Fix a bug that HII type pcd value display extra 0x00
V2: Add Pcd.DatumType check.
Fix a bug that HII type Pcd value display in the report will have an extra 0x00, because original code use StringToArray function and it will judge whether the value length is a multiplier of 2, if not, it will change the value in Pcd Object and add an extra 0x00.
Cc: Bob Feng <bob.c.feng@intel.com>
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Yonghong Zhu <yonghong.zhu@intel.com>
---
BaseTools/Source/Python/AutoGen/AutoGen.py | 7 ++++++-
BaseTools/Source/Python/Workspace/DscBuildData.py | 6 +-----
2 files changed, 7 insertions(+), 6 deletions(-)
diff --git a/BaseTools/Source/Python/AutoGen/AutoGen.py b/BaseTools/Source/Python/AutoGen/AutoGen.py
index 439e360..c8c042b 100644
--- a/BaseTools/Source/Python/AutoGen/AutoGen.py
+++ b/BaseTools/Source/Python/AutoGen/AutoGen.py
@@ -1329,11 +1329,16 @@ class PlatformAutoGen(AutoGen):
continue
if len(Sku.VariableName) > 0:
VariableGuidStructure = Sku.VariableGuidValue
VariableGuid = GuidStructureStringToGuidString(VariableGuidStructure)
for StorageName in Sku.DefaultStoreDict:
- VariableInfo.append_variable(var_info(Index,pcdname,StorageName,SkuName, StringToArray(Sku.VariableName),VariableGuid, Sku.VariableOffset, Sku.VariableAttribute , Sku.HiiDefaultValue,Sku.DefaultStoreDict[StorageName],Pcd.DatumType))
+ HiiValue = Sku.HiiDefaultValue
+ DefaultStoreVal= Sku.DefaultStoreDict[StorageName]
+ if Pcd.DatumType not in [TAB_UINT8, TAB_UINT16, TAB_UINT32, TAB_UINT64, "BOOLEAN"]:
+ HiiValue = StringToArray(Sku.HiiDefaultValue)
+ DefaultStoreVal = StringToArray(Sku.DefaultStoreDict[StorageName])
+
+ VariableInfo.append_variable(var_info(Index,pcdname,StorageName,SkuNam
+ e, StringToArray(Sku.VariableName),VariableGuid, Sku.VariableOffset,
+ Sku.VariableAttribute , HiiValue, DefaultStoreVal,Pcd.DatumType))
Index += 1
return VariableInfo
def UpdateNVStoreMaxSize(self,OrgVpdFile):
if self.VariableInfo:
diff --git a/BaseTools/Source/Python/Workspace/DscBuildData.py b/BaseTools/Source/Python/Workspace/DscBuildData.py
index 9d78770..fc7a307 100644
--- a/BaseTools/Source/Python/Workspace/DscBuildData.py
+++ b/BaseTools/Source/Python/Workspace/DscBuildData.py
@@ -2513,17 +2513,13 @@ class DscBuildData(PlatformBuildClassObject):
else:
MaxSize = 0
if pcd.DatumType not in ['BOOLEAN','UINT8','UINT16','UINT32','UINT64']:
for (_, skuobj) in pcd.SkuInfoList.items():
datalen = 0
- skuobj.HiiDefaultValue = StringToArray(skuobj.HiiDefaultValue)
- datalen = len(skuobj.HiiDefaultValue.split(","))
+ datalen =
+ len((StringToArray(skuobj.HiiDefaultValue)).split(","))
if datalen > MaxSize:
MaxSize = datalen
- for defaultst in skuobj.DefaultStoreDict:
- skuobj.DefaultStoreDict[defaultst] = StringToArray(skuobj.DefaultStoreDict[defaultst])
- pcd.DefaultValue = StringToArray(pcd.DefaultValue)
pcd.MaxDatumSize = str(MaxSize)
rt, invalidhii = self.CheckVariableNameAssignment(Pcds)
if not rt:
invalidpcd = ",".join(invalidhii)
EdkLogger.error('build', PCD_VARIABLE_INFO_ERROR, Message='The same HII PCD must map to the same EFI variable for all SKUs', File=self.MetaFile, ExtraData=invalidpcd)
--
2.6.1.windows.1
^ permalink raw reply related [flat|nested] 2+ messages in thread
end of thread, other threads:[~2018-03-05 7:00 UTC | newest]
Thread overview: 2+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2018-03-05 6:56 [Patch V2] BaseTools: Fix a bug that HII type pcd value display extra 0x00 Yonghong Zhu
2018-03-05 7:06 ` Feng, Bob C
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox